rotational_speed_controller_RSC10.jpg

ROTATIONAL SPEED CONTROLLER RSC10

You can regulate the controller in manual or automatic mode.

​

In the manual mode the rotational speed is within a 0-10 scale.  In Automatic mode the

rotational speed of the turbine's motor is adjusted automatically depending on the air

temperature readings inside the Heat Chamber. After reaching 100F the turbine starts to work with minimal rotational speed. The rotational speed increases as the temperature reading increases. In the Automatic mode, the current temperature reading and rotational

speed (in % of max speed) are shown on the control panel.

​

RSC10 features a High Temperature audio alarm to monitor safe operation of the ADS.

 

TECH DATA:

Power Usage: 6W

Voltage Supply: 240V – 60Hz (120V/240V 200W step-up transformer available)

Regulation Range: 10-100% of rotational speed in manual mode

Max. Ambient temperature: 100°F

Weight: .5 lbs

Warranty: 2 Years -  when installed by licensed electrician

FORCED-AIR-TURBINE.jpg

FORCED AIR TURBINE AT400

The turbine is used to mechanically distribute the hot air from the Heat Chamber located above the fireplace insert or a stove to surrounding rooms.

​

The turbine turns on when the temperature of the air reaches 100°F - factory setting, but can be changed on the RSC10 controller. This appliance moves air through round, insulated ducts. Thanks to the created pressure, it is possible to distribute hot air to several rooms at the same time.

​

Our Turbines are equipped with a filter and a bypass system. The filter helps to clean the air. The bypass system protects the turbine from overheating when the motor is off (e.g.  power outage) or if the temperature of the air in the Heat Chamber is too high.

 

TECH DATA:

Efficiency: 400m3/h

Power Usage: 105W

Operating Voltage: 240V – 60Hz (120V/240V 200W step-up transformer available)

Electrical Breaker: 15A 2-pole

Rotational Speed: 1300 rpm

Diameter: 5"

Noise Level : 42 dBA

Dimensions WxHxD: 20' x 9.75" x 8.25"

Weight: 23.4 lbs

Warranty: 2 Years -  when installed by licensed electrician

FORCED-AIR-TURBINE_2.jpg

FORCED AIR TURBINE AT520

The turbine is used to mechanically distribute the hot air from the Heat Chamber located above

the fireplace insert or a stove to surrounding rooms. 

​

The turbine turns on when the temperature of the air reaches 100°F – factory setting, but can be

changed on the RSC controller. This appliance moves air through round, insulated ducts. Thanks to the created pressure it is possible to distribute hot air to several rooms at the same time.

​

Our Turbines are equipped with a filter and a bypass system. The filter helps to clean the air. 

The bypass system protects the turbine from overheating when the motor is off (e.g.  power outage)

or if the temperature of the air in the Heat Chamber is too high.

 

TECH DATA:

Efficiency: 520m3/h

Power Usage: 112W

Operating Voltage: 240V – 60Hz (120V/240V 200W step-up transformer available)

Electrical Breaker: 15A 2-pole

Rotational Speed: 1280 rpm

Diameter: 6"

Noise Level: 42 dBA

Dimensions WxHxD: 21.75" x 11.25" x 10"

Weight: 27.8 lbs

Warranty: 2 Years -  when installed by licensed electrician

heat_radiator.jpg

HEAT RADIATOR HR150 

The radiator can recover heat from the fumes. This is possible thanks to its ribbing and thick single-wall construction which greatly improves the heating efficiency. 

 

TECH DATA:

Diameter: 6"

Length: 20"

Thermal Resistance: 1830F

Max. temp. of constant work: 1100F

Weight (lbs): 13.25

Warranty:  2 Years 

heat_radiator_2.jpg

HEAT RADIATOR HR200

The radiator can recover heat from the fumes. This is possible thanks to its ribbing and thick single-wall construction which greatly improves the heating efficiency. 

 

TECH DATA:

Diameter: 8"

Length: 20"

Thermal Resistance: 1830F

Max. temp. of constant work: 1100F

Weight (lbs): 18.0

Warranty:  2 Years

distribution_box_545.jpg

DISTRIBUTION BOX DB545

This element is used to distribute hot air from a single heat source to four main 5” diameter flexible ducts.”

 

TECH DATA:

Weight: 3 lbs     
Configuration: 1x5" - 4x5"

Warranty:  2 Years - unconditional 

distribution_box_2.jpg

DISTRIBUTION BOX DB645

This element is used to distribute hot air from a single heat source to four main 5” diameter flexible ducts.

 

TECH DATA:

Weight: 3 lbs     
Configuration: 1x6" - 4x5"

Warranty:  2 Years - unconditional 

reduction_coupler.jpg

REDUCTION COUPLER RC504

This coupler reduces the diameter of the round ducts that distribute the hot air.

 

TECH DATA:

Diameter: 5"/4"

Warranty:  2 Years - unconditional 

reduction_coupler_y.jpg

REDUCTION Y-COUPLER RC524

This Y-coupler splits hot-air distribution ducts.

 

TECH DATA:

Diameter: 5"/2x4"

Warranty:  2 Years - unconditional 

przewod_termoflex.jpg

THERMOFLEX

Flexible aluminium duct, thermally and acoustically insulated used for hot air distribution systems.  Diameter 4" and 5" available at your local home improvement centers.

​

Reduction_Adapter.jpg

REDUCTION ADAPTER
This adapter is used directly on a wood-burning stove or fireplace as the first component of the Fireplace HD system, in case the heating device has a larger exhaust diameter than the heat radiator.

 

Part#::

RA630   Reduction adapter  6.30" ID  to  6"

RA708   Reduction adapter  7.08" ID  to  6"

RA787   Reduction Adapter  7.87" ID  to  6"

RA866   Reduction Adapter  8.66" ID  to  8"

RA905   Reduction Adapter  9.05" ID  to  8"

RA984   Reduction Adapter  9.84" ID  to  8"