ROTATIONAL SPEED CONTROLLER RSC10
You can regulate the controller in manual or automatic mode.
​
In the manual mode the rotational speed is within a 0-10 scale. In Automatic mode the
rotational speed of the turbine's motor is adjusted automatically depending on the air
temperature readings inside the Heat Chamber. After reaching 100F the turbine starts to work with minimal rotational speed. The rotational speed increases as the temperature reading increases. In the Automatic mode, the current temperature reading and rotational
speed (in % of max speed) are shown on the control panel.
​
RSC10 features a High Temperature audio alarm to monitor safe operation of the ADS.
TECH DATA:
Power Usage: 6W
Voltage Supply: 240V – 60Hz (120V/240V 200W step-up transformer available)
Regulation Range: 10-100% of rotational speed in manual mode
Max. Ambient temperature: 100°F
Weight: .5 lbs
Warranty: 2 Years - when installed by licensed electrician
FORCED AIR TURBINE AT400
The turbine is used to mechanically distribute the hot air from the Heat Chamber located above the fireplace insert or a stove to surrounding rooms.
​
The turbine turns on when the temperature of the air reaches 100°F - factory setting, but can be changed on the RSC10 controller. This appliance moves air through round, insulated ducts. Thanks to the created pressure, it is possible to distribute hot air to several rooms at the same time.
​
Our Turbines are equipped with a filter and a bypass system. The filter helps to clean the air. The bypass system protects the turbine from overheating when the motor is off (e.g. power outage) or if the temperature of the air in the Heat Chamber is too high.
TECH DATA:
Efficiency: 400m3/h
Power Usage: 105W
Operating Voltage: 240V – 60Hz (120V/240V 200W step-up transformer available)
Electrical Breaker: 15A 2-pole
Rotational Speed: 1300 rpm
Diameter: 5"
Noise Level : 42 dBA
Dimensions WxHxD: 20' x 9.75" x 8.25"
Weight: 23.4 lbs
Warranty: 2 Years - when installed by licensed electrician
FORCED AIR TURBINE AT520
The turbine is used to mechanically distribute the hot air from the Heat Chamber located above
the fireplace insert or a stove to surrounding rooms.
​
The turbine turns on when the temperature of the air reaches 100°F – factory setting, but can be
changed on the RSC controller. This appliance moves air through round, insulated ducts. Thanks to the created pressure it is possible to distribute hot air to several rooms at the same time.
​
Our Turbines are equipped with a filter and a bypass system. The filter helps to clean the air.
The bypass system protects the turbine from overheating when the motor is off (e.g. power outage)
or if the temperature of the air in the Heat Chamber is too high.
TECH DATA:
Efficiency: 520m3/h
Power Usage: 112W
Operating Voltage: 240V – 60Hz (120V/240V 200W step-up transformer available)
Electrical Breaker: 15A 2-pole
Rotational Speed: 1280 rpm
Diameter: 6"
Noise Level: 42 dBA
Dimensions WxHxD: 21.75" x 11.25" x 10"
Weight: 27.8 lbs
Warranty: 2 Years - when installed by licensed electrician
HEAT RADIATOR HR150
The radiator can recover heat from the fumes. This is possible thanks to its ribbing and thick single-wall construction which greatly improves the heating efficiency.
TECH DATA:
Diameter: 6"
Length: 20"
Thermal Resistance: 1830F
Max. temp. of constant work: 1100F
Weight (lbs): 13.25
Warranty: 2 Years
HEAT RADIATOR HR200
The radiator can recover heat from the fumes. This is possible thanks to its ribbing and thick single-wall construction which greatly improves the heating efficiency.
TECH DATA:
Diameter: 8"
Length: 20"
Thermal Resistance: 1830F
Max. temp. of constant work: 1100F
Weight (lbs): 18.0
Warranty: 2 Years
DISTRIBUTION BOX DB545
This element is used to distribute hot air from a single heat source to four main 5” diameter flexible ducts.”
TECH DATA:
Weight: 3 lbs
Configuration: 1x5" - 4x5"
Warranty: 2 Years - unconditional
DISTRIBUTION BOX DB645
This element is used to distribute hot air from a single heat source to four main 5” diameter flexible ducts.
TECH DATA:
Weight: 3 lbs
Configuration: 1x6" - 4x5"
Warranty: 2 Years - unconditional
REDUCTION COUPLER RC504
This coupler reduces the diameter of the round ducts that distribute the hot air.
TECH DATA:
Diameter: 5"/4"
Warranty: 2 Years - unconditional
REDUCTION Y-COUPLER RC524
This Y-coupler splits hot-air distribution ducts.
TECH DATA:
Diameter: 5"/2x4"
Warranty: 2 Years - unconditional
THERMOFLEX
Flexible aluminium duct, thermally and acoustically insulated used for hot air distribution systems. Diameter 4" and 5" available at your local home improvement centers.
​
REDUCTION ADAPTER
This adapter is used directly on a wood-burning stove or fireplace as the first component of the Fireplace HD system, in case the heating device has a larger exhaust diameter than the heat radiator.
Part#::
RA630 Reduction adapter 6.30" ID to 6"
RA708 Reduction adapter 7.08" ID to 6"
RA787 Reduction Adapter 7.87" ID to 6"
RA866 Reduction Adapter 8.66" ID to 8"
RA905 Reduction Adapter 9.05" ID to 8"
RA984 Reduction Adapter 9.84" ID to 8"
If you have questions about any of these parts or want to know which parts would be best suited for your home-heating needs, please call us at 847-867-7600.